[{"data":1,"prerenderedAt":65},["ShallowReactive",2],{"blog-esd-protection-across-pcb-interfaces-en":3},{"title":4,"description":5,"date":6,"lastUpdated":6,"category":7,"image":8,"imageAlt":9,"readingTime":10,"wordCount":11,"timeRequired":12,"htmlContent":13,"faq":14,"tags":30,"slug":34,"sourceLocale":35,"availableLocales":36,"jsonld":41},"Selecting ESD Protection Across Different PCB Interfaces","Select PCB ESD protection by interface voltage, transient waveform and signal limits, then record the return path and product-level test evidence for each port.","2026-11-24","design",null,"",12,2366,"PT12M","\u003Cp>\u003Cstrong>Choose ESD protection by the port’s electrical limits and the evidence needed to release the product—not by the largest kilovolt number on a device page.\u003C/strong> A GPIO, an industrial bus and a multi-gigabit lane may all need protection from discharge, but they do not share the same operating voltages, fault exposure, signal-loading budget or return path.\u003C/p>\n\u003Cp>Start with the exact circuit on each exposed pin. Then compare candidate protection devices under their stated test conditions, evaluate the current path on the finished board, and validate the assembled product against its applicable test plan.\u003C/p>\n\u003Cp>For HDMI-specific design, use the existing \u003Ca href=\"/en/blog/hdmi-esd-protection/\">HDMI ESD protection guide\u003C/a>. Across interfaces, use a common decision and evidence workflow while retaining each port&#39;s electrical constraints.\u003C/p>\n\u003Cdiv data-component=\"BlogQuickQuoteInline\">\u003C/div>\n\n\u003Ch2>Build the constraint and evidence matrix first\u003C/h2>\n\u003Cp>The examples below illustrate how different the inputs can be. They are \u003Cstrong>not approved bills of materials or system test results\u003C/strong>. Before selecting a part, replace the example assumptions with the actual interface IC, cable, enclosure, operating states and fault requirements.\u003C/p>\n\u003Ctable>\n\u003Cthead>\n\u003Ctr>\n\u003Cth>Interface\u003C/th>\n\u003Cth>Normal and fault voltages\u003C/th>\n\u003Cth>Protection rating and waveform/current evidence\u003C/th>\n\u003Cth>Signal integrity and return-path evidence\u003C/th>\n\u003C/tr>\n\u003C/thead>\n\u003Ctbody>\u003Ctr>\n\u003Ctd>\u003Cstrong>GPIO or audio\u003C/strong>\u003C/td>\n\u003Ctd>Record signal minimum and maximum, supply tolerance, negative excursions, and behavior with the product unpowered. A short circuit or connection to an external supply can last much longer than an ESD pulse. TI’s TPD1E10B06, data sheet \u003Cstrong>SLLSEB1G, August 2024\u003C/strong>, has a bidirectional \u003Cstrong>±5.5 V standoff\u003C/strong>; that alone does not establish compatibility with the circuit or its faults.\u003C/td>\n\u003Ctd>For TPD1E10B06, SLLSEB1G specifies \u003Cstrong>10 V maximum clamping at 1 A\u003C/strong> for a strike at pin 1 with pin 2 grounded and an \u003Cstrong>8/20 µs\u003C/strong> pulse. That is not an ESD-waveform clamp measurement. Its \u003Cstrong>±30 kV IEC 61000-4-2 contact and air device ratings\u003C/strong> are separate evidence, not proof of a finished product’s rating. Establish the actual discharge path and relevant current.\u003C/td>\n\u003Ctd>TPD1E10B06 has \u003Cstrong>12 pF typical I/O capacitance\u003C/strong> at 2.5 V and 1 MHz. Check edge rate, leakage, analog distortion and the complete return path. A slow GPIO may tolerate loading that an audio circuit cannot.\u003C/td>\n\u003C/tr>\n\u003Ctr>\n\u003Ctd>\u003Cstrong>CAN or RS-485\u003C/strong>\u003C/td>\n\u003Ctd>Use the exact transceiver’s normal common-mode, pin, supply and fault limits. For TI \u003Cstrong>TCAN1042H\u003C/strong>, data sheet \u003Cstrong>SLLSES7D, October 2021\u003C/strong>, the normal-mode receiver common-mode specification is \u003Cstrong>−30 V to +30 V\u003C/strong>; the H-version bus absolute maximum is \u003Cstrong>−70 V to +70 V\u003C/strong>. The latter is a fault limit, not a normal operating range. RS-485 limits must be checked separately.\u003C/td>\n\u003Ctd>TCAN1042H’s data sheet reports \u003Cstrong>SOIC CANH/CANL-to-GND IEC contact\u003C/strong> device results of \u003Cstrong>±15 kV unpowered\u003C/strong> and \u003Cstrong>±8 kV powered\u003C/strong>. Those state-dependent results are not actual system branch currents or product-level outcomes. Determine whether the project needs an external network and evaluate it against the applicable ESD, EFT or surge waveform.\u003C/td>\n\u003Ctd>Check bus capacitance, termination, common-mode behavior and cable loading. Trace the discharge return through the connector, protection, board and enclosure as implemented. A protection device must not conduct during legitimate bus conditions or compromise the transceiver’s required fault behavior.\u003C/td>\n\u003C/tr>\n\u003Ctr>\n\u003Ctd>\u003Cstrong>Multi-gigabit interface\u003C/strong>\u003C/td>\n\u003Ctd>Obtain the target interface mode’s actual voltage and common-mode limits, including unpowered and hot-plug conditions. TI’s \u003Cstrong>TPD4E05U06\u003C/strong>, data sheet \u003Cstrong>SLVSBO7O, August 2024\u003C/strong>, has a \u003Cstrong>0 V to 5.5 V recommended signal range\u003C/strong>; this is a device condition, not the operating-voltage definition of every high-speed interface.\u003C/td>\n\u003Ctd>For TPD4E05U06, SLVSBO7O lists \u003Cstrong>±12 kV contact and ±15 kV air IEC 61000-4-2 device ratings\u003C/strong>. Its \u003Cstrong>10 V typical clamp at 1 A\u003C/strong>, I/O to GND, is measured with a \u003Cstrong>100 ns TLP pulse and 200 ps rise time\u003C/strong>—not as the peak at a PHY during a system ESD test.\u003C/td>\n\u003Ctd>The four-channel DQA package has \u003Cstrong>0.5 pF typical line capacitance\u003C/strong> at \u003Cstrong>2.5 V, 1 MHz and 25 °C\u003C/strong>. Include pads, routing and the return path in channel evaluation; use mode-specific eye, loss and compliance evidence. The family’s stated \u003Cstrong>up-to-6 Gbps\u003C/strong> support does not establish suitability for newer, faster modes.\u003C/td>\n\u003C/tr>\n\u003C/tbody>\u003C/table>\n\u003Cp>Keep the supporting records with the matrix: exact ordering code, package, data sheet revision, protected IC revision, test configuration and the person responsible for each unresolved item. Recheck the manufacturer’s current documents before release.\u003C/p>\n\u003Cp>Use one row per exposed port, even when several ports share a connector. Record the normal and fault voltage range, candidate part and package, applicable waveform, channel constraints, intended return path and planned product test. Mark each input as measured, specified or still open. For example, a product with a GPIO connector and a CAN connector needs separate rows: a GPIO candidate&#39;s ±5.5 V standoff does not establish compatibility with the CAN bus. Leave the CAN selection open until its transceiver, bus conditions and fault requirements are known.\u003C/p>\n\u003Ch2>Make four separate decisions\u003C/h2>\n\u003Ch3>1. Confirm the port’s real voltage envelope\u003C/h3>\n\u003Cp>List normal voltages relative to the relevant reference, not just the nominal supply. Include startup, shutdown, unpowered connections, negative signals, common-mode movement and hot plugging. Then identify credible faults and their duration.\u003C/p>\n\u003Cp>The protection device’s standoff voltage must accommodate legitimate operation with acceptable leakage. Its behavior during a longer fault also matters: an ESD-rated part is not automatically sized to absorb a sustained external supply or wiring short.\u003C/p>\n\u003Cp>For example, \u003Cstrong>±5.5 V standoff\u003C/strong> makes TPD1E10B06 a candidate for further examination on a compatible low-voltage GPIO or audio circuit. It does not mean the protected pin can withstand every voltage below or above that figure, nor does it make the device suitable for every bus.\u003C/p>\n\u003Cp>For CAN, do not select a TVS by treating TCAN1042H’s \u003Cstrong>±70 V H-version absolute maximum\u003C/strong> as either normal common mode or a target clamp voltage. Check the transceiver’s operating conditions, external network guidance and fault assumptions together. An absolute maximum is a boundary under specified conditions, not a design operating point or a complete transient-immunity curve.\u003C/p>\n\u003Cp>RS-485 deserves its own check. For example, TI’s \u003Cstrong>THVD1419/THVD1429\u003C/strong>, data sheet \u003Cstrong>SLLSF32C, March 2019\u003C/strong>, specifies \u003Cstrong>−12 V to +12 V\u003C/strong> for an individual bus pin or common-mode voltage under its recommended operating conditions. That figure is not a substitute for the limits of a different RS-485 transceiver.\u003C/p>\n\u003Ch3>2. Match protection evidence to the stress\u003C/h3>\n\u003Cp>Standoff, breakdown, clamping and an ESD rating answer different questions:\u003C/p>\n\u003Cul>\n\u003Cli>\u003Cstrong>Standoff and leakage\u003C/strong> indicate how the device behaves in its intended low-leakage operating region.\u003C/li>\n\u003Cli>\u003Cstrong>Breakdown voltage\u003C/strong> is measured at a specified current; it is not the complete operating clamp.\u003C/li>\n\u003Cli>\u003Cstrong>Clamping voltage\u003C/strong> is meaningful only with its stated polarity, waveform and current.\u003C/li>\n\u003Cli>\u003Cstrong>ESD withstand ratings\u003C/strong> report survival under a named test setup; they do not directly give the protected IC’s pin voltage in an assembled product.\u003C/li>\n\u003C/ul>\n\u003Cp>The TPD1E10B06 \u003Cstrong>10 V maximum at 1 A, 8/20 µs\u003C/strong> value is useful for comparing the specified pulse condition. It cannot be relabeled as the clamp during an IEC ESD strike. Likewise, a TLP curve can help characterize fast transient behavior, but it is not a measurement of the voltage at a particular IC pin in your enclosure.\u003C/p>\n\u003Cp>The actual current divides among available paths and changes with the connector, board, cable, enclosure and discharge location. Compare device data with the protected IC’s transient guidance where available, then verify the implementation. A DC absolute maximum alone rarely describes every allowable short-duration transient.\u003C/p>\n\u003Ch3>3. Spend the signal-integrity budget deliberately\u003C/h3>\n\u003Cp>Protection adds more than a catalog capacitance. Package, pads, routing, reference-plane discontinuities and interactions with neighboring conductors all affect the channel.\u003C/p>\n\u003Cp>For a GPIO, check whether added loading changes timing or input thresholds. For audio, also consider leakage, distortion and the voltage dependence of capacitance. For CAN or RS-485, examine the total bus load, termination and common-mode behavior across the intended cable and node arrangement.\u003C/p>\n\u003Cp>For a multi-gigabit interface, check the target mode’s channel budget and measure the finished channel as required. A low typical capacitance is useful screening evidence, not a universal pass limit. TI’s \u003Cstrong>TPD1E05U06/TPD4E05U06/TPD6E05U06\u003C/strong>, SLVSBO7O, includes application evidence up to \u003Cstrong>6 Gbps\u003C/strong> under the manufacturer’s stated conditions. Do not extrapolate that rating to a newer interface mode with a higher rate or a different channel requirement.\u003C/p>\n\u003Cp>Conversely, \u003Cstrong>TPD1E10B06 is not a multi-gigabit HDMI lane recommendation\u003C/strong>. Its 12 pF typical capacitance and low-speed application context make it a useful contrast, not a shortcut around a high-speed channel assessment.\u003C/p>\n\u003Ch3>4. Evaluate the whole current return\u003C/h3>\n\u003Cp>The protection element only controls part of the transient. Current must travel from the entry point through available conductors and return paths. Trace, pad, package and interconnect inductance can add voltage during a fast current change.\u003C/p>\n\u003Cp>TI’s \u003Cstrong>ESD Protection Layout Guide, SLVA680A, revised April 2022\u003C/strong>, uses the inductive term \u003Ccode>L × dI/dt\u003C/code> to explain this effect. As an explicitly hypothetical illustration:\u003C/p>\n\u003Cul>\n\u003Cli>Path inductance: \u003Cstrong>1 nH\u003C/strong>\u003C/li>\n\u003Cli>Current rate of change: \u003Cstrong>1 A/ns\u003C/strong>\u003C/li>\n\u003Cli>Inductive voltage contribution: \u003Cstrong>1 V\u003C/strong>\u003C/li>\n\u003C/ul>\n\u003Cp>That \u003Cstrong>1 V is not a predicted system peak\u003C/strong>. It excludes the protection device’s dynamic behavior, other parasitics, coupling and the actual current waveform.\u003C/p>\n\u003Cp>Review the path from the exposed entry to the protection node and onward to the intended return, as well as possible coupling into unprotected circuits. The best implementation depends on the board stackup, connector, isolation boundaries, enclosure and interface reference. There is no universal trace geometry, via count or chassis-ground connection that proves the path is adequate.\u003C/p>\n\u003Ch2>Keep test categories separate\u003C/h2>\n\u003Cp>A component qualification and a product immunity test answer different questions.\u003C/p>\n\u003Cul>\n\u003Cli>\u003Cstrong>HBM and CDM\u003C/strong> are component-level ESD qualification models. They address different discharge situations and do not reproduce every product-port event.\u003C/li>\n\u003Cli>\u003Cstrong>IEC 61000-4-2\u003C/strong> defines a system ESD test. A protection device may also carry IEC-based device test ratings, but those ratings do not establish the performance of an assembled product.\u003C/li>\n\u003Cli>\u003Cstrong>Automotive ESD\u003C/strong>, where applicable, may require an automotive-specific plan such as one based on \u003Cstrong>ISO 10605\u003C/strong>. Determine the applicable edition and customer requirements rather than assuming the same setup as an IEC product test.\u003C/li>\n\u003Cli>\u003Cstrong>EFT\u003C/strong>, commonly assessed using \u003Cstrong>IEC 61000-4-4\u003C/strong>, uses bursts of fast transients. It is not interchangeable with a single ESD discharge.\u003C/li>\n\u003Cli>\u003Cstrong>Surge\u003C/strong>, commonly assessed using \u003Cstrong>IEC 61000-4-5\u003C/strong>, uses different waveforms and coupling arrangements. Voltage or current ratings must retain the stated waveform and test setup.\u003C/li>\n\u003C/ul>\n\u003Cp>\u003Ca href=\"/en/blog/esd-control-pcb-assembly/\">Manufacturing ESD controls\u003C/a> remain necessary for handling components, but they do not replace port protection or product immunity validation. Conversely, a product that passes an immunity test still needs appropriate manufacturing handling controls.\u003C/p>\n\u003Ch2>Validate the assembled product, not just the schematic\u003C/h2>\n\u003Cp>The project owner should establish the applicable standard, product requirements and acceptance criteria with the responsible engineering and test teams. The matrix becomes the test plan’s traceability record.\u003C/p>\n\u003Col>\n\u003Cli>\u003Cstrong>Define the configuration.\u003C/strong> Record hardware and firmware revisions, protection part and package, power supply, grounding arrangement, enclosure, cable types and lengths, and connected equipment. Use representative configurations, including relevant worst cases.\u003C/li>\n\u003Cli>\u003Cstrong>Define test states.\u003C/strong> Include the operating modes that matter: powered and unpowered where required, startup or standby, active communication, and realistic peripheral connections.\u003C/li>\n\u003Cli>\u003Cstrong>Define the exposure.\u003C/strong> Document direct and indirect discharge points, contact or air method, polarity, level, repetition and interval according to the applicable standard and approved plan. Do not assume one level applies to all products.\u003C/li>\n\u003Cli>\u003Cstrong>Monitor during the event.\u003C/strong> Capture interface errors, resets, link loss and recovery, corrupted messages, unexpected outputs or analog deviations as appropriate. A product that remains powered is not necessarily functioning correctly.\u003C/li>\n\u003Cli>\u003Cstrong>Apply documented criteria.\u003C/strong> State whether temporary degradation is allowed, whether recovery must be automatic, and whether user intervention, data loss or permanent damage is unacceptable. The applicable requirements determine the criteria.\u003C/li>\n\u003Cli>\u003Cstrong>Verify after testing.\u003C/strong> Repeat relevant functional checks and, where risk warrants, measure leakage, supply current, communication margin, channel performance or analog accuracy. Inspect and investigate anomalies rather than simply replacing a visibly failed TVS.\u003C/li>\n\u003C/ol>\n\u003Cp>When a test fails, examine the event and the system before changing the part. Possible causes include an unsuitable standoff, a sustained fault, excessive loading, coupling, an unexpected return path or inadequate transient capability. Measurements at the protection node and protected IC, made with an appropriate measurement setup, can help distinguish them.\u003C/p>\n\u003Cp>A change to the protection part, footprint, stackup, connector, cable or enclosure can change the result. The project owner should decide what must be re-evaluated and re-tested.\u003C/p>\n\u003Ch2>Release with evidence, not a single rating\u003C/h2>\n\u003Cp>A defensible selection links the port’s operating and fault envelope to an exact device, its waveform-specific data, the signal-integrity budget and the implemented return path. The final decision also records what was actually tested and what remains an assumption.\u003C/p>\n\u003Cp>For a board project, prepare the interface matrix and available design files before requesting a \u003Ca href=\"/en/quote/\">quote\u003C/a>. Keep responsibility for protection selection, applicable requirements and product-level acceptance with the project’s engineering owner.\u003C/p>\n\u003Cp>\u003Cstrong>TI source documents referenced:\u003C/strong> \u003Cem>ESD Protection Layout Guide\u003C/em>, SLVA680A, revised April 2022; \u003Cem>TPD1E10B06\u003C/em>, SLLSEB1G, revised August 2024; \u003Cem>TCAN1042H\u003C/em>, SLLSES7D, revised October 2021; \u003Cem>THVD1419/THVD1429\u003C/em>, SLLSF32C, revised March 2019; and \u003Cem>TPD1E05U06/TPD4E05U06/TPD6E05U06\u003C/em>, SLVSBO7O, revised August 2024.\u003C/p>\n\u003C!-- faq:start -->\n\n\u003Ch2>FAQ\u003C/h2>\n\u003Ch3>Does a higher ESD kilovolt rating make a TVS the better choice?\u003C/h3>\n\u003Cp>Not necessarily. The part must also tolerate normal and fault voltages, limit the relevant transient, meet leakage and signal-loading needs, and work with the implemented return path. Its device rating does not prove product compliance.\u003C/p>\n\u003Ch3>Can I compare a 1 A clamp voltage directly with an IEC ESD strike?\u003C/h3>\n\u003Cp>No. The clamp value belongs to its specified waveform, current and polarity. An IEC discharge produces a different waveform, and the current through a particular device depends on the system paths.\u003C/p>\n\u003Ch3>Is a bidirectional TVS automatically required for a differential bus?\u003C/h3>\n\u003Cp>No. Differential signaling alone does not determine protection polarity. Select the structure using the actual pin voltages relative to the protection reference, including common mode, negative excursions and faults.\u003C/p>\n\u003Ch3>Does a low-capacitance TVS guarantee a high-speed channel will pass?\u003C/h3>\n\u003Cp>No. The quoted capacitance has test conditions and excludes other channel discontinuities. Validate the complete channel against the requirements of the specific interface mode.\u003C/p>\n\u003Ch3>Who decides whether the product has passed ESD testing?\u003C/h3>\n\u003Cp>The project owner is responsible for ensuring that applicable requirements, configurations, monitoring and acceptance criteria are established with the relevant engineering and test teams. The result applies to the tested configuration and plan—not automatically to every revision or installation.\u003C/p>\n\u003C!-- faq:end -->\n\u003Csection class=\"related-links\" aria-label=\"Related\">\u003Ch3>Related links\u003C/h3>\u003Cul>\u003Cli>\u003Ca href=\"/en/blog/hdmi-esd-protection/\">HDMI ESD Protection PCB Design Guide: TVS Diode Selection, Layout Rules, and Validation\u003C/a>\u003C/li>\u003Cli>\u003Ca href=\"/en/blog/esd-control-pcb-assembly/\">ESD Control in PCB Assembly: Handling and Packaging\u003C/a>\u003C/li>\u003Cli>\u003Ca href=\"/en/quote/\">quote\u003C/a>\u003C/li>\u003C/ul>\u003C/section>",[15,18,21,24,27],{"question":16,"answer":17,"answerText":17},"Does a higher ESD kilovolt rating make a TVS the better choice?","Not necessarily. The part must also tolerate normal and fault voltages, limit the relevant transient, meet leakage and signal-loading needs, and work with the implemented return path. Its device rating does not prove product compliance.",{"question":19,"answer":20,"answerText":20},"Can I compare a 1 A clamp voltage directly with an IEC ESD strike?","No. The clamp value belongs to its specified waveform, current and polarity. An IEC discharge produces a different waveform, and the current through a particular device depends on the system paths.",{"question":22,"answer":23,"answerText":23},"Is a bidirectional TVS automatically required for a differential bus?","No. Differential signaling alone does not determine protection polarity. Select the structure using the actual pin voltages relative to the protection reference, including common mode, negative excursions and faults.",{"question":25,"answer":26,"answerText":26},"Does a low-capacitance TVS guarantee a high-speed channel will pass?","No. The quoted capacitance has test conditions and excludes other channel discontinuities. Validate the complete channel against the requirements of the specific interface mode.",{"question":28,"answer":29,"answerText":29},"Who decides whether the product has passed ESD testing?","The project owner is responsible for ensuring that applicable requirements, configurations, monitoring and acceptance criteria are established with the relevant engineering and test teams. The result applies to the tested configuration and plan—not automatically to every revision or installation.",[31,32,33],"ESD protection","PCB interfaces","TVS diode","esd-protection-across-pcb-interfaces","en",[35,37,38,39,40],"de","cn","fr","ru",{"blog":42,"breadcrumb":51},{"@context":43,"@type":44,"headline":4,"description":5,"url":45,"datePublished":6,"dateModified":6,"timeRequired":12,"keywords":46,"articleSection":7,"author":47,"publisher":50},"https://schema.org","BlogPosting","https://hilpcb.com/en/blog/esd-protection-across-pcb-interfaces/","ESD protection, PCB interfaces, TVS diode",{"@type":48,"name":49},"Organization","HILPCB",{"@type":48,"name":49},{"@context":43,"@type":52,"itemListElement":53},"BreadcrumbList",[54,59,63],{"@type":55,"position":56,"name":57,"item":58},"ListItem",1,"Home","https://hilpcb.com/",{"@type":55,"position":60,"name":61,"item":62},2,"Blog","https://hilpcb.com/en/blog/",{"@type":55,"position":64,"name":34,"item":45},3,1795510914373]