[{"data":1,"prerenderedAt":65},["ShallowReactive",2],{"blog-pcb-dip-switch-selection-configuration-en":3},{"title":4,"description":5,"date":6,"lastUpdated":6,"category":7,"image":8,"imageAlt":9,"readingTime":10,"wordCount":11,"timeRequired":12,"htmlContent":13,"faq":14,"tags":30,"slug":34,"sourceLocale":35,"availableLocales":36,"jsonld":41},"How to Select PCB DIP Switches and Verify Configuration Logic","Select a PCB DIP switch for its circuit and assembly process, then verify contact states, input levels, firmware mapping and the required configuration.","2026-11-26","design",null,"",12,2359,"PT12M","\u003Cp>Select a PCB DIP switch by its \u003Cstrong>complete manufacturer part number\u003C/strong>, contact function, electrical load, mechanical fit and compatibility with the assembly process. Then verify the configuration through the entire chain: physical marking, contact state, input level, firmware interpretation and assigned device address.\u003C/p>\n\u003Cp>Those are separate decisions. A marking of \u003Cstrong>ON\u003C/strong> does not universally mean a closed contact, logic 1, a particular actuator direction or the most significant bit. The approved switch documentation, schematic and firmware together establish what a setting means.\u003C/p>\n\u003Ch2>Start with the decision that constrains the design\u003C/h2>\n\u003Cp>Before choosing a switch body, identify what each position must control. A configuration input, for example, may have different contact and reliability requirements from a switch carrying another load. Determine whether the circuit needs independent on/off contacts or another contact arrangement, then check the exact manufacturer’s contact diagram.\u003C/p>\n\u003Cp>Use this matrix to organize the selection. It is a decision aid, not a substitute for the selected part’s data sheet.\u003C/p>\n\u003Ctable>\n\u003Cthead>\n\u003Ctr>\n\u003Cth>Decision\u003C/th>\n\u003Cth>Check before release\u003C/th>\n\u003Cth>If unresolved\u003C/th>\n\u003C/tr>\n\u003C/thead>\n\u003Ctbody>\u003Ctr>\n\u003Ctd>Contact function\u003C/td>\n\u003Ctd>Number of positions, contact arrangement and actual connections in every actuator position\u003C/td>\n\u003Ctd>The footprint may fit while the circuit behaves incorrectly\u003C/td>\n\u003C/tr>\n\u003Ctr>\n\u003Ctd>Electrical suitability\u003C/td>\n\u003Ctd>Switching and carrying conditions, minimum applicable load, signal behavior and the manufacturer’s stated test conditions\u003C/td>\n\u003Ctd>A physically compatible part may not work reliably in the application\u003C/td>\n\u003C/tr>\n\u003Ctr>\n\u003Ctd>Mounting and access\u003C/td>\n\u003Ctd>Through-hole or surface-mount termination, footprint, orientation and actuator clearance\u003C/td>\n\u003Ctd>The part may be difficult to assemble or operate after enclosure installation\u003C/td>\n\u003C/tr>\n\u003Ctr>\n\u003Ctd>Process compatibility\u003C/td>\n\u003Ctd>Exact variant’s sealing, soldering, flux and cleaning restrictions\u003C/td>\n\u003Ctd>A process suitable for the board may damage or contaminate the switch\u003C/td>\n\u003C/tr>\n\u003Ctr>\n\u003Ctd>Configuration meaning\u003C/td>\n\u003Ctd>Switch-to-input mapping, inversion, firmware weighting and address rules\u003C/td>\n\u003Ctd>The visible setting may not produce the expected address\u003C/td>\n\u003C/tr>\n\u003Ctr>\n\u003Ctd>Delivery state\u003C/td>\n\u003Ctd>Approved assembly setting, how it is recorded and how it will be checked\u003C/td>\n\u003Ctd>Boards may leave assembly with an undocumented configuration\u003C/td>\n\u003C/tr>\n\u003C/tbody>\u003C/table>\n\u003Cp>If any of these decisions changes, revisit the others. A substitute with the same number of actuators, for example, can have a different terminal arrangement, body height or cleaning allowance. For the broader approval process, see \u003Ca href=\"/en/blog/pcb-component-substitution-approval/\">PCB component substitution approval\u003C/a>.\u003C/p>\n\u003Ch2>Check the complete switch part number\u003C/h2>\n\u003Cp>A series name or a description such as “four-position DIP switch” is not enough for a bill of materials. Variants can differ in termination, actuator style, sealing, packaging and other features. Record the full manufacturer part number, manufacturer and applicable document revision.\u003C/p>\n\u003Cp>Check the exact variant for:\u003C/p>\n\u003Cul>\n\u003Cli>\u003Cstrong>Contact schematic:\u003C/strong> What is connected in each actuator position? Are positions independent? A multi-position or three-state actuator does not by itself establish high, low or high-impedance input states.\u003C/li>\n\u003Cli>\u003Cstrong>Terminals and footprint:\u003C/strong> Do the manufacturer’s dimensions and contact diagram match the schematic symbol, PCB land pattern and assembly drawing? Do not assume that one switch’s terminal numbering applies to another.\u003C/li>\n\u003Cli>\u003Cstrong>Electrical conditions:\u003C/strong> Does the part support the actual voltage, current and load type? Distinguish switching from carrying ratings where the manufacturer does so, and check any minimum-load conditions and their stated test conditions.\u003C/li>\n\u003Cli>\u003Cstrong>Mechanical envelope:\u003C/strong> Can the part fit within the board outline and enclosure while leaving access to the actuator and its markings?\u003C/li>\n\u003Cli>\u003Cstrong>Supply state:\u003C/strong> What configuration does the manufacturer specify on delivery, if any? Treat that separately from the configuration required for the finished board.\u003C/li>\n\u003C/ul>\n\u003Cp>For low-level signals, also consider whether the specified contact behavior is suitable for the circuit over its intended conditions. A maximum rating alone does not prove reliable operation at a much smaller signal level.\u003C/p>\n\u003Ch2>Fit the switch to the assembly process\u003C/h2>\n\u003Cp>Choose the mounting style and actuator access with the assembler and mechanical design in mind. A surface-mount part must have a compatible footprint and soldering process; a through-hole part must fit the board and the planned soldering sequence. Check body height, actuator travel, nearby components and whether a tool can reach the switch once the product is assembled.\u003C/p>\n\u003Cp>A seal or protective tape is a \u003Cstrong>variant-specific process feature\u003C/strong>, not blanket permission to wash a board. Check the selected part’s manufacturer documentation for the allowed soldering and cleaning conditions, seal state, compatible materials and any instructions for handling or removing protection. Then confirm that the complete board process is compatible. Other components, flux residues and board features can affect that decision.\u003C/p>\n\u003Cp>For example, the Omron A6H datasheet distinguishes standard models from seal-tape models in its washing information. That distinction applies to the variants and conditions in that document; it does not approve a particular cleaning method for another switch or a complete assembly.\u003C/p>\n\u003Cp>Do not substitute a generic cleaning recipe for this review. The \u003Ca href=\"/en/blog/no-clean-flux-residue/\">no-clean flux residue guide\u003C/a> provides context for board-level decisions; it does not certify a cleaning process for a particular switch.\u003C/p>\n\u003Ch2>Separate the five layers of configuration\u003C/h2>\n\u003Cp>A reliable design package makes each of these layers explicit:\u003C/p>\n\u003Col>\n\u003Cli>\u003Cstrong>Physical ON marking:\u003C/strong> What does the marking refer to on the selected part, and from which view is the switch shown?\u003C/li>\n\u003Cli>\u003Cstrong>Contact state:\u003C/strong> Which terminals are connected or disconnected in that actuator position?\u003C/li>\n\u003Cli>\u003Cstrong>Input electrical level:\u003C/strong> Given the actual surrounding circuit and valid supply conditions, what level reaches the input?\u003C/li>\n\u003Cli>\u003Cstrong>Firmware bit mapping:\u003C/strong> Which input becomes which bit, and does software invert or otherwise transform it?\u003C/li>\n\u003Cli>\u003Cstrong>Assigned device address:\u003C/strong> How does the product define an address from those bits, if it uses them for an address at all?\u003C/li>\n\u003C/ol>\n\u003Cp>The physical marking is useful for operation, but it cannot replace the contact diagram or the circuit. An open contact may produce a high level, a low level or an undefined level depending on the design. Likewise, a high input may be interpreted as a zero or a one in a software-defined configuration field.\u003C/p>\n\u003Ch3>Hypothetical GPIO example\u003C/h3>\n\u003Cp>The following is an \u003Cstrong>explicitly hypothetical generic GPIO example\u003C/strong>. It is not a specific product, a certified design or a recommended connection for any particular IC.\u003C/p>\n\u003Cp>Assume:\u003C/p>\n\u003Cul>\n\u003Cli>S1, S2, S3 and S4 map respectively to bits b0, b1, b2 and b3.\u003C/li>\n\u003Cli>Each input has an independent pullup, and its switch contact closes that input to ground.\u003C/li>\n\u003Cli>The supply and input conditions are valid, so an open contact reads high and a closed contact reads low.\u003C/li>\n\u003Cli>S1 and S3 are closed; S2 and S4 are open.\u003C/li>\n\u003Cli>Separately, software defines an \u003Cstrong>ON bit\u003C/strong> as 1 when its contact is closed. This definition does not establish what any physical ON marking means.\u003C/li>\n\u003C/ul>\n\u003Cp>Each of the four independent channels follows this conceptual connection:\u003C/p>\n\u003Cpre>\u003Ccode class=\"language-text\">valid supply -- pullup --+-- GPIO input (b0, b1, b2 or b3)\n                         |\n                    switch contact\n                         |\n                        ground\n\u003C/code>\u003C/pre>\n\u003Cp>The diagram shows the stated logic only. Select the resistor, voltage domain, input thresholds and contact load for the real circuit; it is not a complete schematic or a real switch pinout.\u003C/p>\n\u003Ctable>\n\u003Cthead>\n\u003Ctr>\n\u003Cth>Switch\u003C/th>\n\u003Cth align=\"right\">Mapped bit\u003C/th>\n\u003Cth>Contact state\u003C/th>\n\u003Cth align=\"right\">Input level\u003C/th>\n\u003Cth align=\"right\">Software ON bit\u003C/th>\n\u003C/tr>\n\u003C/thead>\n\u003Ctbody>\u003Ctr>\n\u003Ctd>S1\u003C/td>\n\u003Ctd align=\"right\">b0\u003C/td>\n\u003Ctd>Closed\u003C/td>\n\u003Ctd align=\"right\">0\u003C/td>\n\u003Ctd align=\"right\">1\u003C/td>\n\u003C/tr>\n\u003Ctr>\n\u003Ctd>S2\u003C/td>\n\u003Ctd align=\"right\">b1\u003C/td>\n\u003Ctd>Open\u003C/td>\n\u003Ctd align=\"right\">1\u003C/td>\n\u003Ctd align=\"right\">0\u003C/td>\n\u003C/tr>\n\u003Ctr>\n\u003Ctd>S3\u003C/td>\n\u003Ctd align=\"right\">b2\u003C/td>\n\u003Ctd>Closed\u003C/td>\n\u003Ctd align=\"right\">0\u003C/td>\n\u003Ctd align=\"right\">1\u003C/td>\n\u003C/tr>\n\u003Ctr>\n\u003Ctd>S4\u003C/td>\n\u003Ctd align=\"right\">b3\u003C/td>\n\u003Ctd>Open\u003C/td>\n\u003Ctd align=\"right\">1\u003C/td>\n\u003Ctd align=\"right\">0\u003C/td>\n\u003C/tr>\n\u003C/tbody>\u003C/table>\n\u003Cp>Writing the bits in \u003Cstrong>b3..b0\u003C/strong> order gives two different descriptions of the same contact states:\u003C/p>\n\u003Cul>\n\u003Cli>\u003Cstrong>Input levels:\u003C/strong> \u003Ccode>1010₂\u003C/code> = decimal \u003Cstrong>10\u003C/strong>\u003C/li>\n\u003Cli>\u003Cstrong>Software ON bit map:\u003C/strong> \u003Ccode>0101₂\u003C/code> = decimal \u003Cstrong>5\u003C/strong>\u003C/li>\n\u003C/ul>\n\u003Cp>Neither number is automatically a device address. The product’s firmware could use either representation, transform it, reject it or use the switches for something other than addressing. The example also says nothing about the physical direction of any actuator or the terminal numbering of a real switch.\u003C/p>\n\u003Ch3>Record a mapping check\u003C/h3>\n\u003Cp>For the same fictional mapping, a test plan could compare one closed contact at a time with all others open. The table lists expected values, not results from a tested board. \u003Ccode>b3..b0\u003C/code> is the raw input level; the ON bitmap uses the separately defined closed-is-one convention above.\u003C/p>\n\u003Ctable>\n\u003Cthead>\n\u003Ctr>\n\u003Cth>Closed contact\u003C/th>\n\u003Cth>Expected input levels\u003C/th>\n\u003Cth>Expected ON bitmap\u003C/th>\n\u003C/tr>\n\u003C/thead>\n\u003Ctbody>\u003Ctr>\n\u003Ctd>None\u003C/td>\n\u003Ctd>\u003Ccode>1111\u003C/code>\u003C/td>\n\u003Ctd>\u003Ccode>0000\u003C/code>\u003C/td>\n\u003C/tr>\n\u003Ctr>\n\u003Ctd>S1 only\u003C/td>\n\u003Ctd>\u003Ccode>1110\u003C/code>\u003C/td>\n\u003Ctd>\u003Ccode>0001\u003C/code>\u003C/td>\n\u003C/tr>\n\u003Ctr>\n\u003Ctd>S2 only\u003C/td>\n\u003Ctd>\u003Ccode>1101\u003C/code>\u003C/td>\n\u003Ctd>\u003Ccode>0010\u003C/code>\u003C/td>\n\u003C/tr>\n\u003Ctr>\n\u003Ctd>S3 only\u003C/td>\n\u003Ctd>\u003Ccode>1011\u003C/code>\u003C/td>\n\u003Ctd>\u003Ccode>0100\u003C/code>\u003C/td>\n\u003C/tr>\n\u003Ctr>\n\u003Ctd>S4 only\u003C/td>\n\u003Ctd>\u003Ccode>0111\u003C/code>\u003C/td>\n\u003Ctd>\u003Ccode>1000\u003C/code>\u003C/td>\n\u003C/tr>\n\u003C/tbody>\u003C/table>\n\u003Cp>For a real product, identify the board, firmware revision, physical switch view, allowed test states, test conditions and expected observable firmware result. Record the actual result and disposition for every step. Follow the authorized procedure for setting the switch and applying power: some products sample only at startup, and a live setting change may not be permitted. A mismatch needs investigation before release; this example cannot verify the hardware or assign a device address.\u003C/p>\n\u003Cdiv data-component=\"BlogQuickQuoteInline\">\u003C/div>\n\n\u003Ch2>Define how a setting becomes an address\u003C/h2>\n\u003Cp>The schematic and firmware specification should make the conversion reproducible without relying on a photograph alone. Document:\u003C/p>\n\u003Cul>\n\u003Cli>The switch position associated with each electrical input and the input’s bit weight.\u003C/li>\n\u003Cli>Any inversion between the measured input level and the firmware field.\u003C/li>\n\u003Cli>Any transformation, such as an offset, lookup table or combination with another configuration source.\u003C/li>\n\u003Cli>Which values are valid, invalid or reserved, and what the device does when it reads one.\u003C/li>\n\u003Cli>How address uniqueness or collisions are handled in the intended system.\u003C/li>\n\u003Cli>When inputs are sampled and when a changed configuration takes effect.\u003C/li>\n\u003Cli>How the resulting value is displayed or reported, including whether it is decimal, hexadecimal or another representation.\u003C/li>\n\u003C/ul>\n\u003Cp>Where an interface distinguishes an address from a transmitted address field or direction bit, the documentation should name the representation expected by the relevant software interface. Do not assume that every number associated with communication is the device address.\u003C/p>\n\u003Cp>Also specify behavior at startup, when power is not valid and when a contact or input is faulty. An apparent actuator position alone cannot demonstrate that the input is electrically sound. Follow the device’s authorized configuration and safety procedure; do not assume that a running or energized system permits a setting change.\u003C/p>\n\u003Ch2>Make the drawing unambiguous\u003C/h2>\n\u003Cp>An assembly drawing should show the switch as the assembler and inspector will see it. State the viewing direction, board side, reference designator and orientation. Identify individual switch positions in that view and relate them to the schematic and firmware names.\u003C/p>\n\u003Cp>For a required configuration, specify the intended \u003Cstrong>contact or actuator state according to the selected part’s documentation\u003C/strong>, rather than relying only on phrases such as “left is ON.” If a photograph or diagram is used, label its view and revision. Check that the markings remain visible after installation and that the board’s enclosure does not obstruct access.\u003C/p>\n\u003Cp>The configuration record should distinguish:\u003C/p>\n\u003Cul>\n\u003Cli>The switch manufacturer’s supplied state, if specified.\u003C/li>\n\u003Cli>The state required at assembly or shipment.\u003C/li>\n\u003Cli>Any later configuration controlled by a separate product procedure.\u003C/li>\n\u003C/ul>\n\u003Cp>That distinction prevents a default supplied by a component manufacturer from being mistaken for an approved product setting.\u003C/p>\n\u003Ch2>RFQ and release checklist\u003C/h2>\n\u003Cp>An RFQ should give the supplier and assembler enough information to identify the part and flag process conflicts. The final release should resolve those questions before production. Use the \u003Ca href=\"/en/quote/\">quote page\u003C/a> to submit a request when appropriate. To discuss the project or clarify an open question, \u003Ca href=\"/en/contact/\">contact HILPCB\u003C/a>.\u003C/p>\n\u003Ch3>For the RFQ\u003C/h3>\n\u003Cul>\n\u003Cli>\u003Cinput disabled=\"\" type=\"checkbox\"> Provide the board revision, quantity and assembly documentation available for review.\u003C/li>\n\u003Cli>\u003Cinput disabled=\"\" type=\"checkbox\"> List the full switch manufacturer part number, manufacturer, reference designator and quantity per board.\u003C/li>\n\u003Cli>\u003Cinput disabled=\"\" type=\"checkbox\"> Supply the footprint and outline requirements, including height and actuator access constraints.\u003C/li>\n\u003Cli>\u003Cinput disabled=\"\" type=\"checkbox\"> Identify the intended soldering, flux and cleaning requirements, and ask for any compatibility questions to be raised.\u003C/li>\n\u003Cli>\u003Cinput disabled=\"\" type=\"checkbox\"> Identify whether a particular switch configuration must be delivered and how it will be communicated.\u003C/li>\n\u003Cli>\u003Cinput disabled=\"\" type=\"checkbox\"> Flag any proposed alternate part for approval; do not treat a similar appearance as approval.\u003C/li>\n\u003C/ul>\n\u003Ch3>Before release\u003C/h3>\n\u003Cul>\n\u003Cli>\u003Cinput disabled=\"\" type=\"checkbox\"> Match the schematic contact diagram and terminal mapping to the selected manufacturer documentation and PCB footprint.\u003C/li>\n\u003Cli>\u003Cinput disabled=\"\" type=\"checkbox\"> Confirm electrical suitability for the real load and applicable rated conditions.\u003C/li>\n\u003Cli>\u003Cinput disabled=\"\" type=\"checkbox\"> Confirm that the complete assembly process is permitted for the exact switch variant and compatible with the board.\u003C/li>\n\u003Cli>\u003Cinput disabled=\"\" type=\"checkbox\"> Release the assembly view, switch orientation, position identifiers and required configuration under revision control.\u003C/li>\n\u003Cli>\u003Cinput disabled=\"\" type=\"checkbox\"> Link the switch-to-input map to the approved firmware revision and address rules.\u003C/li>\n\u003Cli>\u003Cinput disabled=\"\" type=\"checkbox\"> Define the authorized inspection or test method, acceptance criteria and records, including how discrepancies will be handled.\u003C/li>\n\u003Cli>\u003Cinput disabled=\"\" type=\"checkbox\"> Communicate approved substitutions, configuration changes and affected document revisions to both supplier and assembler.\u003C/li>\n\u003C/ul>\n\u003Cp>Where electrical verification is specified, define the test conditions and account for the surrounding circuit; an in-circuit measurement may not isolate a contact. Use the product’s authorized safety and test procedures. General component-selection context is available in the \u003Ca href=\"/en/blog/circuit-board-components/\">circuit board components guide\u003C/a>.\u003C/p>\n\u003C!-- faq:start -->\n\n\u003Ch2>FAQ\u003C/h2>\n\u003Ch3>Does ON always mean logic 1?\u003C/h3>\n\u003Cp>No. ON is a physical marking whose relationship to the contact must be checked for the selected switch. The circuit determines the input level, and firmware determines how that level is represented.\u003C/p>\n\u003Ch3>Can I calculate a device address directly from the switch positions?\u003C/h3>\n\u003Cp>Only if the product documentation defines that calculation. Verify position-to-bit mapping, inversion, weighting, transformations and invalid or reserved values before assigning an address.\u003C/p>\n\u003Ch3>Is a sealed DIP switch always washable?\u003C/h3>\n\u003Cp>No. Sealing or tape may support particular processes under stated conditions. Check the complete part number and manufacturer instructions, then assess compatibility with the complete board process.\u003C/p>\n\u003Ch3>Can a different DIP switch with the same number of positions be substituted?\u003C/h3>\n\u003Cp>Not automatically. Compare contact function, terminal mapping, footprint, actuator access, electrical conditions and process compatibility. Release an alternate only through the applicable approval process.\u003C/p>\n\u003Ch3>When does a new switch setting take effect?\u003C/h3>\n\u003Cp>That is product-specific. Firmware may sample inputs at a defined time and apply changes according to its own rules. Consult the device’s configuration and safety instructions rather than assuming an immediate change.\u003C/p>\n\u003C!-- faq:end -->\n\u003Csection class=\"related-links\" aria-label=\"Related\">\u003Ch3>Related links\u003C/h3>\u003Cul>\u003Cli>\u003Ca href=\"/en/blog/pcb-component-substitution-approval/\">PCB Component Substitution: An Approval Checklist\u003C/a>\u003C/li>\u003Cli>\u003Ca href=\"/en/blog/no-clean-flux-residue/\">No-Clean Flux Residue: When to Leave It, Clean It or Validate It\u003C/a>\u003C/li>\u003Cli>\u003Ca href=\"/en/quote/\">quote page\u003C/a>\u003C/li>\u003Cli>\u003Ca href=\"/en/contact/\">contact HILPCB\u003C/a>\u003C/li>\u003Cli>\u003Ca href=\"/en/blog/circuit-board-components/\">Circuit Board Components: Common PCB Parts, What They Do and How to Identify Them\u003C/a>\u003C/li>\u003C/ul>\u003C/section>",[15,18,21,24,27],{"question":16,"answer":17,"answerText":17},"Does ON always mean logic 1?","No. ON is a physical marking whose relationship to the contact must be checked for the selected switch. The circuit determines the input level, and firmware determines how that level is represented.",{"question":19,"answer":20,"answerText":20},"Can I calculate a device address directly from the switch positions?","Only if the product documentation defines that calculation. Verify position-to-bit mapping, inversion, weighting, transformations and invalid or reserved values before assigning an address.",{"question":22,"answer":23,"answerText":23},"Is a sealed DIP switch always washable?","No. Sealing or tape may support particular processes under stated conditions. Check the complete part number and manufacturer instructions, then assess compatibility with the complete board process.",{"question":25,"answer":26,"answerText":26},"Can a different DIP switch with the same number of positions be substituted?","Not automatically. Compare contact function, terminal mapping, footprint, actuator access, electrical conditions and process compatibility. Release an alternate only through the applicable approval process.",{"question":28,"answer":29,"answerText":29},"When does a new switch setting take effect?","That is product-specific. Firmware may sample inputs at a defined time and apply changes according to its own rules. Consult the device’s configuration and safety instructions rather than assuming an immediate change.",[31,32,33],"DIP switch","PCB assembly","device configuration","pcb-dip-switch-selection-configuration","en",[35,37,38,39,40],"de","cn","fr","ru",{"blog":42,"breadcrumb":51},{"@context":43,"@type":44,"headline":4,"description":5,"url":45,"datePublished":6,"dateModified":6,"timeRequired":12,"keywords":46,"articleSection":7,"author":47,"publisher":50},"https://schema.org","BlogPosting","https://hilpcb.com/en/blog/pcb-dip-switch-selection-configuration/","DIP switch, PCB assembly, device configuration",{"@type":48,"name":49},"Organization","HILPCB",{"@type":48,"name":49},{"@context":43,"@type":52,"itemListElement":53},"BreadcrumbList",[54,59,63],{"@type":55,"position":56,"name":57,"item":58},"ListItem",1,"Home","https://hilpcb.com/",{"@type":55,"position":60,"name":61,"item":62},2,"Blog","https://hilpcb.com/en/blog/",{"@type":55,"position":64,"name":34,"item":45},3,1795625459638]