Choose the exact manufacturer part before assigning PCB pins or enclosure labels. Confirm its contact states, transition timing, switching rating, terminal drawing, footprint and assembly restrictions. Then map each circuit net to the manufacturer’s terminal number and verify both end states on an isolated sample.
An SPDT switch has one common contact that selects between two throws. Common describes the contact’s role; it is not inherently an input. Depending on the circuit, it can connect one signal to either of two destinations or connect either of two signals to one destination.
Do not assume the common is the middle physical pin, that a maintained switch has a universal “normal” position, or that moving an actuator in a particular direction selects a particular terminal. Those are exact-part and viewing-direction questions.
Start with the contact state your circuit needs
For the matrix below, C means common and A and B mean the two throws. These are functional names, not manufacturer pin numbers or physical positions.
| Contact state or event | Circuit consequence | Design decision |
|---|---|---|
| C connected to A | The A path is selected; B is not the selected path. | Confirm the intended A circuit can tolerate the switch’s resistance, leakage and current conditions. |
| C connected to B | The B path is selected; A is not the selected path. | Apply the same checks to B. Do not infer which actuator direction produces this state. |
| Neither path connected during transfer | A break-before-make transfer can interrupt power or leave a signal node floating. | Decide whether interruption is acceptable. If a signal needs a defined state, design and verify a suitable bias or hold function. |
| Both paths connected during transfer | A make-before-break transfer can briefly connect A and B through the switch. | Check what happens if the two paths are joined. Two incompatible sources may require a different architecture, not just a different label. |
| Contacts bounce during movement or settling | The receiving circuit may see multiple changes rather than one clean edge. | Define the acceptable response and validate an application-specific hardware or firmware treatment. |
The first two rows describe end states. The transition rows are not additional maintained positions. An SPDT switch may have a center-off position, but SPDT alone does not promise one.

Functional contacts only; the diagram does not show the actual pin layout or transition behavior.
For example, a switch can select one of two signals for a high-impedance input. A break-before-make part may leave that input undefined during transfer; a suitably designed bias may address that circuit condition. A make-before-break part may instead connect the two signal sources together. Their output structures and the resulting current must be checked before that arrangement is accepted.
The same concern applies when routing a supply to one of two loads: overlap may energize both paths, while a break may interrupt the load. Contact selection is therefore a circuit decision, not merely a choice between two actuator positions.
Decide what “normal” and transition timing mean
A maintained switch stays in its selected position until moved. It has no universal normal position. Use “normally open” and “normally closed” only when the exact component defines a normal state—for example, a specified rest state for a momentary device. For a maintained selector, a contact-state description is usually clearer.
Two transition styles matter:
- Break-before-make, also called non-shorting, opens the outgoing path before closing the incoming path. The interval can interrupt a supply or float a node.
- Make-before-break, also called shorting, closes the incoming path before opening the outgoing path. The overlap can connect the two throws.
Those descriptions do not, by themselves, give a guaranteed break interval, overlap duration or bounce profile. If timing is critical, obtain applicable manufacturer data and assess the actual circuit using a suitable dynamic measurement plan.
Debouncing addresses how a circuit interprets contact changes. It cannot prevent make-before-break contact overlap, remove an unsafe source connection or make an inadequately rated circuit safe.
Use exact-part examples, not a generic pinout
These manufacturer examples illustrate why the schematic, mechanical drawing and rating conditions must stay attached to the complete part number.
Nidec Components CSS-1210MC
Nidec Components' CSS-1210MC product information and CSS series drawing describe an individual, side-actuated, through-hole switch with no self-return. Its contact action is non-shorting.
In the manufacturer’s CSS-1210C schematic, terminal 3 is C, and terminals 1 and 2 are the other contacts. This example alone defeats the assumption that common must be the middle terminal.
The specified ratings include:
- Switching: 12 VDC, 100 mA.
- Non-switching: 50 VDC, 100 mA.
- Minimum: 20 mVDC, 1 µA, as stated for the series.
The non-switching figure is not permission to switch the same current at 50 VDC. The manufacturer also marks the series non-washable, which must be reconciled with the proposed assembly and cleaning process.
The series drawing supplies the terminal and PCB processing views. Use those views together, then verify the installed actuator-to-contact mapping; do not infer a physical direction from the schematic alone.
NKK Switches SS12SDP2
NKK Switches' SS12SDP2 part information and SS series catalog describe a top-actuated, through-hole SPDT slide switch. It is shorting, or make-before-break.
The catalog circuit chart identifies terminal 2 as common, with terminals 1 and 3 as the throws. The terminal numbers are not physically marked on the switch. Its ON–NONE–ON notation does not establish a maintained center-off position.
For this exact part, the catalog states an electrical capacity of 0.1 A at 30 VDC for a resistive load. Do not extend that condition to an inductive load or invent a separate carry rating.
The manufacturer's catalog has a slide-position convention, but its mapping to the actual installed view must be confirmed before assigning enclosure labels. NKK's CN-0414 notice identifies specific discontinued products; check whether any notice applies to the complete ordering code and confirm current lifecycle and supply status before release.
Match the rating to the electrical duty
A current printed beside a voltage is not a complete load analysis. Review the exact datasheet and the actual circuit for:
- Switching versus carrying: Current interrupted or established by moving contacts can have a different rating from current carried through already-closed contacts.
- AC versus DC: Do not substitute one rating for the other. Use the manufacturer’s stated conditions.
- Load type and inrush: A capacitive input or a lamp-like load may draw more current at connection than its steady-state value suggests.
- Inductive transients: Coils and other inductive loads can produce voltage transients at opening. Select suppression for the particular load and circuit, and verify that it does not create another unwanted path.
- Minimum signal conditions: Very low-current signals may need contacts and conditions suitable for that duty. Check the manufacturer’s minimum specification rather than assuming any power-rated contact will perform adequately.
- Temperature and endurance: Check applicable environmental limits and the required operating life under the actual load.
A dielectric withstand figure is not a working-voltage or switching rating. Where hazardous voltage is involved, the design also needs appropriate protection, clearances, enclosure provisions and applicable safety review.
Map and verify the wiring before layout release
Begin with the manufacturer’s contact diagram and numbering for the full ordering code. Determine which terminal is common and which two are the throws. Assign circuit nets to those terminal numbers in the schematic; do not assign nets according to where pins appear in a generic SPDT symbol.
Next, interpret the mechanical drawing’s view. A terminal-side view, component-side PCB view and enclosure view can appear reversed relative to one another. Record the view and orientation used for the footprint and any actuator markings.
For an isolated continuity check, qualified personnel should isolate all power, verify stored energy is discharged, and use rated equipment and approved procedures. The measurement must not be confused by parallel circuit paths. Check C against each throw in each stable actuator position and compare the result with the intended net and label mapping.
An isolated continuity measurement checks end states only. It does not establish transient overlap, break duration, bounce, lifetime performance or a voltage rating. If the transition matters, use an appropriately designed dynamic test with suitable instrumentation and protection, under an approved procedure. A sample measurement supports the assessment; it does not replace specified limits or prove every production unit will behave identically.
Exact-part-to-PCB release checklist
Complete this checklist for the same ordering code in the schematic, bill of materials, footprint and assembly documentation.
- Part identity: Record manufacturer, complete part number, datasheet or drawing revision, actuator style, terminal style and any ordering options. Check lifecycle and sourcing status before committing to the part.
- Contact table: Record the manufacturer’s common and throw terminal numbers and the intended connections in each stable position. Do not add NO/NC or center-off labels unless supported by the part definition.
- Transition decision: Record whether the part is shorting or non-shorting. Document the circuit consequence of overlap or interruption and any required dynamic verification.
- Electrical approval: Check switching and carry conditions separately, including AC/DC, load type, inrush, transients, minimum signal conditions, temperature and required life.
- Symbol-to-footprint mapping: Match each schematic pin number to the numbered physical terminal. Check the drawing’s view direction and resolve any apparent mirror image before release.
- Mechanical fit: Check body outline, board edge, actuator travel, enclosure opening, operating access and clearance to neighboring parts. Confirm that labels describe the installed orientation, not an assumed view.
- PCB geometry: Use the manufacturer’s recommended land or hole pattern and tolerances for the exact terminal style. Review hole size, pitch, pads, solder mask and any required mechanical support.
- Assembly process: Check permitted soldering conditions, cleaning compatibility and handling requirements. A non-washable part needs an approved process that respects that restriction.
- Sample and documentation: Compare an isolated sample with the drawing, footprint and intended labels. Resolve discrepancies before freezing the design; record the approved orientation and any unresolved manufacturer questions.
- Release package: Provide the controlled BOM, PCB files, assembly drawing, orientation notes and relevant process constraints to the parties reviewing fabrication and assembly.
For another approach to switching signals, see reed relay selection for PCB signal switching. The guide to electronic component failure modes also covers how component conditions affect reliability.
If requesting a board or assembly quotation, include the switch part number and the relevant assembly constraints with the project information. Request a quote.
FAQ
Is the common terminal always the middle pin?
No. Common is a contact role. In the Nidec CSS-1210MC series drawing discussed above, terminal 3 is common; in the NKK SS12SDP2 chart, terminal 2 is common. Use the exact manufacturer drawing.
Can an SPDT switch select between two power sources?
It can be used in a source-selection circuit only if the complete design is suitable. A make-before-break switch can momentarily connect the sources; a break-before-make switch can interrupt the output. Ratings, protection and transition consequences require circuit-level review.
Does ON–NONE–ON mean center-off?
Not necessarily. In the cited NKK SS12SDP2 catalog, “NONE” does not identify a maintained center-off detent. Check the exact part’s position and contact table rather than interpreting the notation in isolation.
How do SPDT, DPDT and DIP switches differ?
SPDT describes one pole selecting between two throws. DPDT has two mechanically linked poles, each selecting between two throws. DIP describes a package form; depending on the model, a DIP switch can contain one or more SPST or SPDT elements. Check the exact part's contact table and terminal layout.
Can a continuity meter prove that a switch is break-before-make?
No. An isolated continuity check can identify stable end-state connections, but it cannot establish a brief break interval, overlap or bounce. Use manufacturer information and suitable dynamic measurement when transition behavior matters.